Fluid Sampling Systems
|
Fluid
Sampling Systems
|
|
Crude oil
prices necessitate accurate measurement of the BS&W content in
oil. Manual sampling methods can result in samples with inaccurate
and inconsistent values.
Automatic
Fluid Sampling Systems
- Designed
to collect continuous, representative samples of oil and
BS&W
- Dependable
sampling permits accurate determination of the BS&W
percentage
|
| Economy
Impulse-Actuated Electric Sampler For Flow Controlled Sampling
When Connected to Fluid Meter or Time-Controlled Sampling When
Connected to Timer |
|
- Egineered
for proportionate to flow sampling controlled by a fluid meter
or other electrical impulse source
- Cost-efficient
for crude oil sampling on LACT units
- Flexible
installation: sample probe installed in pipeline; line can be
powered from meter or timed to solenoid
- Features
0 to 2.5 cubic centimeter-capacity adjustable sample volume
regulator; solenoid-operated, explosion-proof three-way
sampling valve and fluid inlet pressure regulator
- Assembled
on convenient mounting bracket
- Sample
volume regulator for larger size samples, from 0 to 10 cubic
centimeters, is available
- Supplied
without pressure regulator and gauge for sampling when line
pressure is below 50 pounds per square inch and relatively
constant
- Three-way
solenoid sampling valve can be supplied "normally
closed" for sample entry during the "power-on"
time of the cycle
- Solenoid
valves are available for most power characteristics
- A
complete line of accessories includes McFarland sample probes,
sample containers and sample houses
- Units can
be modified for timer-controlled operations
|
Economy
HP for uses up to 1,000 psi. No pressure regulator
Net
Weight: 10lbs.
Shipping Cube: 8ft.
|
|
|
| Economac
Impulse-Actuated Sampler With Motor-Driven, Slip-Stream
Circulating Pump For Flow-Controlled or Time-Controlled Sampling |
- Features
1/2 horsepower, 3.5 gallon-per-minute, motor-driven pump for
slip-stream circulating along with the standard Economy
Sampler components
- Circulates
fluid through the probe and by the solenoid sampling valve at
adequate velocity to keep water and solids in suspension
- Permits
the installation of the sampler remote from the pipeline
- Motors
available for most requirements
- Installation
similar to the Economy Sampler, but with an added return
circulation line
- Provides
constant-volume sampling when used with a timer
- Sampling
rates are fixed for any single setting of the timer, but other
rates can be obtained by manual resetting of the timer
- Can be
customized for use with the Economac Sampler

|
|
Impeller-Type
Sampler For Flow Controlled Sampling
(Proportional to
Flow)
|
- Installed
as an integral part of the pipeline
- No
outside power or control is required
- Features
an impeller-driven sampling probe and sample circulation
return probe assembled to a blind flange and mounted on a
tee-flanged outlet positioned inside pipeline
- Incorporates
a rotary sampling valve, McFarland sample volume regulator,
inlet probe, return probe piping with shut-off valves and
fluid pressure regulator
- Rotary
sampling valve and fluid-powered impeller control sampling
frequency
- Adjustable
sample volume regulator, from 0 to 2.5 cubic centimeters
controls sample size
- Rotary
sampling valve alternately connects the volume regulator to
the probe for filling or to the sample container for emptying
- Rotary
sample valve, sample volume regulator and probe arrangement
designed to permit passage of sand and BS&W through the
sampler without clogging or damage
- No check
valves are required- eliminating the potential for cutting or
plugging
- Will
mount on blind flange without tee or on existing pipelines by
addition of a saddle, flanged outlet and hot tap
- A 24-inch
sampler is provided for lines above 24 inches-customer should
advise dimension from center of pipeline to face of the
sampler mounting flange
- Can be
supplied mounted on flanged side outlet of a plain end tee,
beveled for welding into the pipeline
- Flange
size and pressure rating are matched to line requirements
- Sample
volume regulator capacity: 0 to 10 cubic centimeters
- Special
volume regulators available for large sample sizes
- Accessories
include sample container, sheet-metal house, companion
flanges, and studs and gaskets
- Fluid
flow provides the power and controls the sampling rate
- Changes
in the sampling rate are directly proportional to changes in
the flow rate in the pipeline
- Installed
in horizontal or vertical lines in accordance with API
sampling standards
| Nominal
Pipe Size (in.) |
Appoximate
Barrels Transmitted/Sample |
150
lb. Mounting Flanges |
300
lb. Mounting Flanges |
| Length
Flange to Flange (in.) |
Width
(in.) |
Height
C/L to Top (in.) |
Length
Flange to Flange (in.) |
Width
(in.) |
Height
C/L to Top (in.) |
| 2
1/2* |
1.0 |
22
1/4 |
11 |
18
7/8 |
22
1/4 |
12
1/2 |
19
3/8 |
| 3* |
.8 |
22
1/4 |
11 |
18
7/8 |
22
1/4 |
12
1/2 |
19
3/8 |
| 4* |
.6 |
22
1/4 |
11 |
18
7/8 |
22
1/4 |
12
1/2 |
19
3/8 |
| 6 |
.5 |
11
1/4 |
11 |
18
7/8 |
11
1/4 |
12
1/2 |
19
3/8 |
| 8 |
1.5 |
14 |
13
1/2 |
20 |
14 |
15 |
20
1/2 |
| 10 |
3.0 |
17 |
16 |
21
1/8 |
17 |
17
1/2 |
21
3/4 |
| 12 |
7.0 |
20 |
19 |
24
1/8 |
20 |
20
1/2 |
24
7/8 |
| 14 |
10.0 |
22 |
21 |
25
3/8 |
22 |
23 |
26
1/8 |
| 16 |
14.0 |
24 |
23
1/2 |
26
5/8 |
24 |
25
1/2 |
27
3/8 |
| 18 |
17.0 |
27 |
25 |
27
3/8 |
27 |
28 |
29
1/8 |
| 20 |
24.0 |
30 |
27
1/2 |
30
1/8 |
30 |
30
1/2 |
30
7/8 |
| 24 |
33.0 |
34 |
32 |
32
1/2 |
34 |
36 |
33
3/8 |
|
|
*Standard
6” sampler with end reducers used under 6”
Note: Maximum unit sample volume: 10 cc.

|
|
Fluid
Sampling Systems
| Vapor-Proof,
Clear-View Sample Container |
- Features
a unique method of vapor-sealing samples removed from the
pipeline until removal for analysis-as the container fills,
the Hycar synthetic rubber diaphragm is raised by the sample
surface, maintaining a vapor seal and indicating the quantity
of sample collected
- Trouble-free
design provides easy and quick dismantling for cleaning
- Aluminum
bottom-half of the bowl is epoxy coated to prevent water and
other substances from sticking to the sides of the container
as fluid is withdrawn
- Hand-operated
circulating pump is standard
- Will
mount on the container's base

|
Pipeline
Probes For Sampling
(Shown are four McFarland probes for typical
pipeline installation) |
- Slip-stream,
return circulation probes are designed for use with the
Economac Sampler
- Probes
and method of installation can be customized to meet your
specific requirements
- Diameter
of pipeline must be given for probe to be centered on pipeline

|
| Cone
Bottom (Metal) Sample Container |
|
- Features
cone-type bottom, gauge glass, hand-operated circulating mixer
pump; three-way valve for mixing or-drawing sample from
container; and relief valve with a 5- to 13-pound adjustable
spring
- Container
is coated internally and mounted on tripod legs
- Easily
removable top for cleaning
- Can be
customized for your specific requirements
- Will
mount directly on the container's base
- Standard
hand-operated circulating pump can be replaced with optional
motor-driven circulating pump
- Pump is
designed for mixing sample, pumping sample to the transporting
container and pumping surplus sample back into the pumpline
- Container
can be specified with special protective coating
- Available
in 5- to 30-gallon capacities

| Capacity
(Gal.) |
Dimensions
(in.) |
| A |
B |
C |
D |
E |
F |
| 5 |
15 |
7
1/2 |
5
1/2 |
20 |
4 |
6 |
| 10 |
15 |
7
1/2 |
14 |
22
3/4 |
12
1/2 |
5
1/8 |
| 20 |
15 |
7
1/2 |
27 |
22
3/4 |
28
5/8 |
5
1/8 |
| 30 |
19 |
9
1/2 |
25 |
23
1/2 |
23
1/4 |
5
1/8 |
|
Home
| Main | Enquiry
|
|
|
|